中国海油供应商**开发公开征集公示
中国海油因CAMBO FPSO项目工作需要,诚邀具备研发能力、制造能力和相关业绩的国内外优秀供应商,与中国海油共同开展工作。现将相关采办包信息公开如下:
1.需求概况
管壳式热交换器:数量12台
关键技术参数:
①1st STAGE LP COMPRESSOR SUCTION COOLER ×2
Rated Flowrate (kg/h): TS: 2394 SS: 16348
Duty (MW): 0.5
Operating Pressure (barg):TS: 0.46 (IN) 0.36 (OUT) SS: 10 (IN) 9.9 (OUT)
Design Pressure (barg): TS: FV/15 SS: FV/15 (HOLD 3)
Operating Temperature (°C): TS: 104~128 (IN) 35 (OUT) SS: 20 (IN), 45 (OUT)
Design Temperature Max (°C): TS: 160 SS: 160 (HOLD 3)
Design Temperature Min (°C): TS: -46 SS: -46
②1st STAGE LP COMPRESSOR DISCHARGE COOLER×2
Rated Flowrate (kg/h): TS: 1844 SS: 3681
Duty (MW): 0.145
Operating Pressure (barg):TS: 3.5 (IN), 2.6 (OUT) SS: 10 (IN), 9.9 (OUT)
Design Pressure (barg): TS: FV/15 SS: FV/15 (HOLD 3)
Operating Temperature (°C): TS: 133~154 (IN), 50 (OUT) SS: 20 (IN), 45 (OUT)
Design Temperature Max (°C): TS: 185 SS: 185 (HOLD 3)
Design Temperature Min (°C): TS: -46 SS: -46
③2nd STAGE LP COMPRESSOR DISCHARGE COOLER ×2
Rated Flowrate (kg/h): TS: 1833 SS: 5456
Duty (MW): 0.16
Operating Pressure (barg):TS: 9 (IN), 8.3 (OUT) SS: 10 (IN), 9.9 (OUT)
Design Pressure (barg): TS: FV/15 SS: FV/15 (HOLD 3)
Operating Temperature (°C): TS: 139~159 (IN), 50 (OUT) SS: 20 (IN), 45 (OUT)
Design Temperature Max (°C): TS: 190 SS: 190 (HOLD 3)
Design Temperature Min (°C): TS: -46 SS: -46
④1st STAGE HP COMPRESSOR DISCHARGE COOLER ×2
1. Rated Flowrate (kg/h): TS: 31517 SS: 51248
Duty (MW): 1.67
Operating Pressure (barg):TS: 27.6 (IN) 26.9 (OUT) SS: 10 (IN) 9.9 (OUT)
Design Pressure (barg): TS: FV/45 SS: FV/45 (HOLD 2)
Operating Temperature (°C): TS: 131 (IN), 45 (OUT) SS: 20 (IN), 45 (OUT)
Design Temperature Max (°C): TS: 165 SS: 165 (HOLD 2)
Design Temperature Min (°C): TS: -46 SS: -46
2. Rated Flowrate (kg/h): TS: 31517 SS: 51248
Duty (MW): 1.678
Operating Pressure (barg):TS: 27.6 (IN) 26.9 (OUT) SS: 10.1 (IN), 10 (OUT)
Design Pressure (barg): TS: FV/92 SS: FV/92 (HOLD 2)
Operating Temperature (°C): TS: 115 (IN), 45 (OUT) SS: 20 (IN), 45 (OUT)
Design Temperature Max (°C): TS: 185 SS: 185 (HOLD 2)
Design Temperature Min (°C): TS: -46 SS: -46
⑤2nd STAGE HP COMPRESSOR DISCHARGE COOLER×2
Rated Flowrate (kg/h): TS: 31517 SS: 88829
Duty (MW): 2.84
Operating Pressure (barg):TS: 73 (IN), 72.3 (OUT) SS: 10.0(IN), 9.9 (OUT)
Design Pressure (barg): TS: FV/92 SS: FV/92 (HOLD 2)
Operating Temperature (°C): TS: 144~145 (IN), 35 (OUT) SS: 20 (IN), 45 (OUT)
Design Temperature Max (°C): TS: 175 SS: 175(HOLD 2)
Design Temperature Min (°C): TS: -46 SS: -46
⑥ GAS IMPORT HEAT EXCHANGER×2
Rated Flowrate (kg/h): TS: HOLD SS: HOLD
Duty (MW): 0.798
Operating Pressure (barg):HOT SIDE: 9.8 (IN),9.1 (OUT)
COOL SIDE: 196.5 (IN), 195.8 (OUT)
Design Pressure (barg): HOT SIDE: 292 COOL SIDE: 292
Operating Temperature (°C): HOT SIDE: 140 (IN), 105 (OUT)
COOL SIDE: -6.3 (IN), 69.5 (OUT)
Design Temperature Max (°C): HOT SIDE: 170 COOL SIDE: 170
Design Temperature Min (°C): TS: -46 SS: -46
2.对供应商的要求
1)投标人应为制造商。本次招标不接受代理商、贸易商投标。本次接受所投货物的****公司****公司,以及接受所****公司参与投标,此类公司视同为制造商,需提供相应的证明文件。
2)投标人所投产品须具备CE或UKCA认证(现有或承诺提供)。
3****公司简****公司简介说明,相关厂房、车间、制造设备、检验设备、人员等的说明及照片等)、营业执照、业绩 (英国或欧洲海上项目业绩优先),业绩证明文件包括但不限于:1)销售合同复印件和2)到货验收材料。业绩证明文件必须至少体现以下内容:合同签署时间、货物名称、制造商、到货验收材料。
3.项目联系人
请感兴趣的供应商于2026年2月28日前,与我方联系人接洽。
联系人:杨若彤
电 话:(022) 5989 9126
邮 箱:ex_yangrt2@cnooc.****.cn
(****)
2026年2月10日
附件下载1标书代写