物品名称 规格型号 数量 单位 描述
| 点火控制箱 |
详见描述 |
4.00 |
套 |
{"型号":"500*400*250","配电箱的高度":"500mm","配电箱的宽度":"400mm","配电箱的深度":"252mm","配电箱铁皮的厚度":"1.5mm","安装方式":"明挂","外壳材质":"304不锈钢","特殊要求":"防护等级IP54","使用寿命":"1825天","参照标准":"GB/T 7251.1-2023","备注":"供货时按照需方要求预留相应孔洞,根据需方要求在柜门贴有指示或操作标识牌;箱门设置弹跳锁,箱内设置安装背板,在背板上配置标准DIN导轨及线槽,根据需方要求进行箱内配接线(含箱内配接电缆);供方提供以下电气元件:1个小型断路器(220VAC、2P、C10、进口品牌),4个中间继电器及底座(220VAC、6A、4NO+NC、带手动按钮及指示灯、进口品牌),2个红色指示灯(220VAC),2个绿色指示灯(220VAC),1个红色按钮(NO、220VAC),1个绿色按钮(NO、220VAC),20个UK接线端子;验收标准:1、物资到货附带产品合格证2、到货与技术要求不符时,供应商无条件退换货处理,产生的费用由供应商承担。"} |
| 吊扇电容 |
详见描述 |
2.00 |
套 |
{"规格型号":"2.2UF","产品分类":"低压电容","额定电压":"0.45kV","额定输出":"0.2Kvar","额定频率":"50Hz","容量":"2.2μF","使用寿命":"1095天","外壳材质":"外壳塑料","参照标准":"GB/T 3667.1-2016","备注":"图片仅做参考,长35~40mm,宽25~30mm,厚:16~19mm,容量偏差±5%,工作温度,不低于70℃,与技术要求不符,退换货处理!"} |
| 交流接触器 |
详见描述 |
3.00 |
套 |
{"规格型号":"CDC6-185-44 AC380-400V","额定电压":"AC690V","额定电流":"185A","频率":"50HZ","线圈电压":"AC380~400V","材质":"触点为铜质合金材料,外壳采用高绝缘阻燃工程塑料。","使用寿命":"≥1095天","适用对象":"电动机","参照标准":"GB 14048.4-2010","备注":"辅助触头数量:4常开,四常闭。\n验收标准:包装完好,内部备件无破碎、损坏,外观、材质等必须符合以上所示技术要求,元件若有升级,出具升级前后元件的外观、尺寸、性能等方面的差异证明一份,如不符合验收标准,退换货或全额退款"} |
| 指示灯 |
详见描述 |
2.00 |
套 |
{"规格型号":"LD1122D41M3","额定电压":"220V","开孔尺寸":"Ф22mm","安装方式":"自固式","可选颜色":"绿色","材质":"PC塑料外壳","使用寿命":"1250天","适用对象":"电气回路电源指示","参照标准":"GB/T 14048.5-2017","备注":"进口/国产信息:国产,验货标准:1、由于产品升级或停产导致设备型号不一致,但接口尺寸等参数满足现场生产需要,设备厂家出具相关证明,办理入库。2、设备型号一致,但接口尺寸等参数不能满足现场生产需要,退货处理。3、外观破损、变形、受潮、附件缺失,退货处理。"} |
| 铠装热电阻 |
详见描述 |
4.00 |
套 |
{"型号":"Pt100/φ6/L=300","测量范围":"20~200℃","分度号":"PT100","长度":"300mm","温杆直径":"Ф6mm","线制":"三线制","检测元件数量":"1","接口规格":"M16*1.5mm(活动卡套螺纹)","防爆防护等级":"IP65","保护管材质":"304不锈钢","生产厂家":"国产","特殊要求":"接线采用快速接插式,带活动卡套及卡箍(304不锈钢),可任意调整插深","参照标准":"GB/T 30121-2013","备注":"精度等级:B级;使用寿命:12个月;物资到货附带产品合格证;验收标准:到货与技术要求不符时,供应商无条件退换货处理,产生的费用由供应商承担。"} |
| 铠装热电阻 |
详见描述 |
3.00 |
套 |
{"型号":"Pt100/φ6/L=400","测量范围":"-20~200℃","分度号":"PT100","长度":"400mm","温杆直径":"Ф6mm","线制":"三线制","检测元件数量":"1","接口规格":"M20*2mm(活动卡套螺纹)","防爆防护等级":"IP65","保护管材质":"304不锈钢","生产厂家":"国产","特殊要求":"接线采用快速接插式,带活动卡套及卡箍(304不锈钢),可任意调整插深","参照标准":"GB/T 30121-2013","备注":"精度等级:B级;使用寿命:12个月;物资到货附带产品合格证;验收标准:到货与技术要求不符时,供应商无条件退换货处理,产生的费用由供应商承担。"} |
| 铠装热电阻 |
详见描述 |
2.00 |
套 |
{"型号":"Pt100/φ12/L=300","测量范围":"-20~200℃","分度号":"PT100","长度":"300mm","温杆直径":"Ф12mm","线制":"三线制","检测元件数量":"1","接口规格":"M27*2mm(活动卡套螺纹)","防爆防护等级":"IP65","保护管材质":"304不锈钢","生产厂家":"国产","特殊要求":"接线采用快速接插式,带活动卡套及卡箍(304不锈钢),可任意调整插深","参照标准":"GB/T 30121-2013","备注":"精度等级:B级;使用寿命:12个月;物资到货附带产品合格证;验收标准:到货与技术要求不符时,供应商无条件退换货处理,产生的费用由供应商承担。"} |
| S型热电偶 |
详见描述 |
3.00 |
套 |
{"型号":"S/900/Ф16","测量范围":"0~1600℃","分度号":"S","长度":"900*750mm","保护管直径":"Ф16mm","线制":"两线制/单支","精度等级":"Ⅱ级","接口规格":"M27*2.0,固定螺纹","防爆防护等级":"IP65","铠装护套材质":"保护管为3YC52","生产厂家":"国产","特殊要求":"热电偶偶丝直径0.5mm;偶丝外套刚玉管,直径6mm","参照标准":"GB/T 30429-2013","备注":"使用寿命:8个月;保护管单侧壁厚4mm,保护管要求采用整棒钻孔;配带防水型接线盒,接线盒采用铸铝材质;配退火紫铜垫;物资到货附带产品合格证;验收标准:到货与技术要求不符时,供应商无条件退换货处理,产生的费用由供应商承担。"} |
| 隔膜耐震压力表 |
详见描述 |
2.00 |
套 |
{"测量范围":"0~10MPa","精度等级":"1.6","接口规格":"DN50PN100HG/T20592~20635-2009","安装方式":"法兰连接径向","表盘直径":"100mm","防震要求":"耐震型","表壳材质":"表壳为SS304,隔离膜片为HC-276,本体法兰SS304","型号":"10MPa/DN50/PN100","参照标准":"GB/T 1226-2017","备注":"耐震型,表壳为SS304,隔离膜片为HC-276,本体法兰SS3043,密封面形式:RJ环连接面,使用寿命:≥1年,质量验收要求:该到货产品与上述要求不符,对该到货产品调换退货"} |
| 全不锈钢耐震法兰隔膜压力表 |
详见描述 |
15.00 |
套 |
{"测量范围":"0-0.6MPa","精度等级":"1.6","接口规格":"DN80 PN16","安装方式":"径向","表盘直径":"150mm","防震要求":"耐震型","表壳材质":"304不锈钢","型号":"Y-150/0.6Mpa/DN80","参照标准":"GB/T 1226-2017","备注":"使用寿命:12个月;隔离膜片材质:HC-276;本体法兰材质:304不锈钢;法兰执行标准:HG/T 20592-2009; 膜片型式:平膜片;物资到货附带产品合格证;验收标准:到货与技术要求不符时,供应商无条件退换货处理,产生的费用由供应商承担。"} |
| 全不锈钢耐震法兰隔膜压力表 |
详见描述 |
1.00 |
套 |
{"测量范围":"0-1.6MPa","精度等级":"1.6","接口规格":"DN80 PN16","安装方式":"径向","表盘直径":"150mm","防震要求":"耐震型","表壳材质":"304不锈钢","型号":"Y-150/1.6Mpa/DN80","参照标准":"GB/T 1226-2017","备注":"使用寿命:12个月;隔离膜片材质:HC-276;本体法兰材质:304不锈钢;法兰执行标准:HG/T 20592-2009; 膜片型式:平膜片;物资到货附带产品合格证;验收标准:到货与技术要求不符时,供应商无条件退换货处理,产生的费用由供应商承担。"} |